{"id":1840,"date":"2023-07-20T06:25:12","date_gmt":"2023-07-20T06:25:12","guid":{"rendered":"https:\/\/www.koenigconveyors.com\/in\/?p=1840"},"modified":"2023-07-25T06:23:43","modified_gmt":"2023-07-25T06:23:43","slug":"flow-control-valves-enhance-efficiency","status":"publish","type":"post","link":"https:\/\/www.koenigconveyors.com\/in\/flow-control-valves-enhance-efficiency\/","title":{"rendered":"Flow Control Valves: Enhancing Efficiency and Performance"},"content":{"rendered":"<div  class='flex_column av-7t4x9s-327d2d6b1bdf9f93cfcd3c963cd07a0b av_one_full  avia-builder-el-0  el_before_av_one_full  avia-builder-el-first  first flex_column_div  '     ><p>\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-lkarnn75-495bfe54acafe14fd918596af99aee85\">\n.avia-image-container.av-lkarnn75-495bfe54acafe14fd918596af99aee85 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-lkarnn75-495bfe54acafe14fd918596af99aee85 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-lkarnn75-495bfe54acafe14fd918596af99aee85 av-styling- avia-align-center  avia-builder-el-1  el_before_av_hr  avia-builder-el-first '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img decoding=\"async\" fetchpriority=\"high\" class='wp-image-1890 avia-img-lazy-loading-not-1890 avia_image ' src=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-115250.png\" alt='' title='Screenshot 2023-07-20 115250'  height=\"414\" width=\"408\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-115250.png 408w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-115250-296x300.png 296w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-115250-80x80.png 80w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-115250-36x36.png 36w\" sizes=\"(max-width: 408px) 100vw, 408px\" \/><\/div><\/div><\/div><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-lkavbsyy-58b2aac510530cc03b2023b227d4a8be\">\n#top .hr.hr-invisible.av-lkavbsyy-58b2aac510530cc03b2023b227d4a8be{\nheight:50px;\n}\n<\/style>\n<div  class='hr av-lkavbsyy-58b2aac510530cc03b2023b227d4a8be hr-invisible  avia-builder-el-2  el_after_av_image  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-lk9o97z7-251bbed9dc799336d7d1842380b088f1 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h2>Introduction to Flow Control Valves<\/h2>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-lk9ocbkk-845d368916d4937cb0358ec49778ca21 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><p><a href=\"https:\/\/www.koenigconveyors.com\/in\/koenig-flow-control-valves\/\">Flow control valves<\/a> are used to regulate the material withdrawal from <a href=\"https:\/\/www.koenigconveyors.com\/in\/storage-silos-manufacturers-in-india-chennai\/\">silos<\/a>, bins etc. when mounted along with <a href=\"https:\/\/www.koenigconveyors.com\/in\/koenig-pneuslide\/\">PneuSlide<\/a> (Pneumatic Air Activated Gravity Conveyor). These valves are designed to manage the flow of materials, ensuring optimal performance and efficiency. In this article, we will explore the various types of flow control valves, their functions, and the benefits they offer in different industries.<\/p>\n<\/div><\/section><\/p><\/div><div  class='flex_column av-5xssr4-6143473781c38bc3a5b32ff742e2b378 av_one_full  avia-builder-el-5  el_after_av_one_full  el_before_av_one_full  first flex_column_div  column-top-margin'     ><section  class='av_textblock_section av-lk9oegqh-8703408fcd207bc1943aea8b36c87fe0 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h2>Table of Contents<\/h2>\n<\/div><\/section><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-qfhif4-3adc75d6d9ea0133a369f27cf2c1cd65\">\n#top .hr.hr-invisible.av-qfhif4-3adc75d6d9ea0133a369f27cf2c1cd65{\nheight:50px;\n}\n<\/style>\n<div  class='hr av-qfhif4-3adc75d6d9ea0133a369f27cf2c1cd65 hr-invisible  avia-builder-el-7  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-lk9ohffu-438959e9efb7079d6d7fe3b6454c912a '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><ol>\n<li><a href=\"#understanding\">Understanding Flow Control Valves<\/a>\n<ol>\n<li><a href=\"#whatarethey\">What are Flow Control Valves?<\/a><\/li>\n<li><a href=\"#valveswork\">How do Flow Control Valves Work?<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#types\">Types of Flow Control Valves<\/a>\n<ol>\n<li><a href=\"#manualvalve\">Manual Actuated Valve<\/a><\/li>\n<li><a href=\"#pneumaticfcv\">Pneumatic controlled Flow Control Valve<\/a><\/li>\n<li><a href=\"#motorfcv\">Motor controlled Flow control Valve<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#roller\">How Roller type affects flow<\/a><\/li>\n<li><a href=\"#factors\">Factors to consider before choosing the right Flow Control Valve<\/a>\n<ol>\n<li><a href=\"#actuation\">Actuation<\/a><\/li>\n<li><a href=\"#material\">Material<\/a><\/li>\n<li><a href=\"#frr\">Flow Rate Requirements<\/a><\/li>\n<li><a href=\"#maintenance\">Maintenance Requirements<\/a><\/li>\n<\/ol>\n<\/li>\n<li><a href=\"#case\">Use case: Cement Industries<\/a><\/li>\n<li><a href=\"#conclusion\">Conclusion<\/a><\/li>\n<\/ol>\n<\/div><\/section><\/p><\/div><div  class='flex_column av-dv83k-158b702653bf8eb8bf1e6c196193ceb1 av_one_full  avia-builder-el-9  el_after_av_one_full  el_before_av_one_full  first flex_column_div  column-top-margin'     ><section  id=\"understanding\"  class='av_textblock_section av-lk9onmjg-9cf44d40f58d788b1a558292a8226971 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h2>Understanding Flow Control Valves<\/h2>\n<\/div><\/section><\/div><\/p>\n<div  class='flex_column av-382x8g-373d5cf0b877dd9f9afa559127533b78 av_one_full  avia-builder-el-11  el_after_av_one_full  el_before_av_one_full  first flex_column_div  column-top-margin'     ><section  id=\"whatarethey\"  class='av_textblock_section av-lk9ozbkr-ab92bcde536e6b151eef9487aa44bd79 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>What are Flow Control Valves?<\/h3>\n<\/div><\/section><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-oplxio-a6635b4980101c5561b5f53fe55c365e\">\n#top .hr.hr-invisible.av-oplxio-a6635b4980101c5561b5f53fe55c365e{\nheight:50px;\n}\n<\/style>\n<div  class='hr av-oplxio-a6635b4980101c5561b5f53fe55c365e hr-invisible  avia-builder-el-13  el_after_av_textblock  el_before_av_image '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-lk9puxrs-ea9141816f3e99ed8198ec2a23704f40\">\n.avia-image-container.av-lk9puxrs-ea9141816f3e99ed8198ec2a23704f40 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-lk9puxrs-ea9141816f3e99ed8198ec2a23704f40 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-lk9puxrs-ea9141816f3e99ed8198ec2a23704f40 av-styling- avia-align-center  avia-builder-el-14  el_after_av_hr  el_before_av_hr '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img decoding=\"async\" fetchpriority=\"high\" class='wp-image-1851 avia-img-lazy-loading-not-1851 avia_image ' src=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-19-175209-300x258.png\" alt='Flow Control Valves' title='Flow Control Valves'  height=\"258\" width=\"300\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-19-175209-300x258.png 300w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-19-175209.png 357w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div><\/div><\/div><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-m2u5g0-eed13b56e93b7d4825522e93c297ade2\">\n#top .hr.hr-invisible.av-m2u5g0-eed13b56e93b7d4825522e93c297ade2{\nheight:50px;\n}\n<\/style>\n<div  class='hr av-m2u5g0-eed13b56e93b7d4825522e93c297ade2 hr-invisible  avia-builder-el-15  el_after_av_image  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-lk9pz8ip-6009482661df0b88128ef95c05e3204d '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><p>For the regulated discharge of pulverized bulk commodities like <a href=\"https:\/\/en.wikipedia.org\/wiki\/Cement\">cement<\/a>, <a href=\"https:\/\/en.wikipedia.org\/wiki\/Lime_(material)\">lime<\/a>, <a href=\"https:\/\/en.wikipedia.org\/wiki\/Gypsum\">gypsum<\/a>, and <a href=\"https:\/\/en.wikipedia.org\/wiki\/Fly_ash\">fly ash<\/a>, flow control valves are used to close off the discharge spouts of silos. An unhindered flowthrough is guaranteed by flow control valves. The picture above shows the flow control valve.<\/p>\n<\/div><\/section><\/p><\/div><div  class='flex_column av-dee2w0-75fc52a8d1840fcb6d82e4a19400562b av_one_full  avia-builder-el-17  el_after_av_one_full  el_before_av_one_full  first flex_column_div  column-top-margin'     ><section  id=\"valveswork\"  class='av_textblock_section av-lkaoztjj-d291a99dd7bc546a4202b9ef622bbb58 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>How do Flow Control Valves Work?<\/h3>\n<\/div><\/section><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-kbcp7k-41c5a8071477a2d2be490feaae77a159\">\n#top .hr.hr-invisible.av-kbcp7k-41c5a8071477a2d2be490feaae77a159{\nheight:50px;\n}\n<\/style>\n<div  class='hr av-kbcp7k-41c5a8071477a2d2be490feaae77a159 hr-invisible  avia-builder-el-19  el_after_av_textblock  el_before_av_image '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-lkap0k9s-2cdd18abffc859daeca6ad07df06c5e1\">\n.avia-image-container.av-lkap0k9s-2cdd18abffc859daeca6ad07df06c5e1 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-lkap0k9s-2cdd18abffc859daeca6ad07df06c5e1 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-lkap0k9s-2cdd18abffc859daeca6ad07df06c5e1 av-styling- avia-align-center  avia-builder-el-20  el_after_av_hr  el_before_av_textblock '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img decoding=\"async\" fetchpriority=\"high\" class='wp-image-1865 avia-img-lazy-loading-not-1865 avia_image ' src=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-102759-240x300.png\" alt='Flow Control Valve' title='Flow Control Valve'  height=\"300\" width=\"240\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-102759-240x300.png 240w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-102759-564x705.png 564w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-102759.png 646w\" sizes=\"(max-width: 240px) 100vw, 240px\" \/><\/div><\/div><\/div><br \/>\n<section  class='av_textblock_section av-lkap2ex7-a93198331e038b7319b1439f865e84fd '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><p>The flow control valve is an element to be placed between fluid slides. It consists of an upper box (A) which forms the conveying chamber and a lower box (B) which is supplied with compressed air. Upper and lower box are separated from each other by a fabric permeable to air.<\/p>\n<p>When the roller rotates into one direction, the silo discharge opening is closed, when the roller rotates into the other direction, the adjustable aperture is opened, so that the fluidized bulk good can flow through.<\/p>\n<\/div><\/section><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-jtfrm8-de5318ae51669508835d15afda5bbbdc\">\n#top .hr.hr-invisible.av-jtfrm8-de5318ae51669508835d15afda5bbbdc{\nheight:50px;\n}\n<\/style>\n<div  class='hr av-jtfrm8-de5318ae51669508835d15afda5bbbdc hr-invisible  avia-builder-el-22  el_after_av_textblock  el_before_av_image '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-lkap5oyf-7f3e454ab5196081a066962033473a36\">\n.avia-image-container.av-lkap5oyf-7f3e454ab5196081a066962033473a36 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-lkap5oyf-7f3e454ab5196081a066962033473a36 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-lkap5oyf-7f3e454ab5196081a066962033473a36 av-styling- avia-align-center  avia-builder-el-23  el_after_av_hr  avia-builder-el-last '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img decoding=\"async\" fetchpriority=\"high\" class='wp-image-1868 avia-img-lazy-loading-not-1868 avia_image ' src=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-104257.png\" alt='Flow Control Valve' title='Flow Control Valve'  height=\"449\" width=\"874\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-104257.png 874w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-104257-300x154.png 300w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-104257-768x395.png 768w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-104257-705x362.png 705w\" sizes=\"(max-width: 874px) 100vw, 874px\" \/><\/div><\/div><\/div><\/p><\/div><div  class='flex_column av-i24qv4-072d68ea5fa1fa72686cf22ec0768b81 av_one_full  avia-builder-el-24  el_after_av_one_full  el_before_av_one_full  first flex_column_div  column-top-margin'     ><section  id=\"valveswork\"  class='av_textblock_section av-lkav89fg-692d0a4a351a4f8e81686526e5faeec5 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h2>How Roller type affects flow in Flow Control Valves<\/h2>\n<\/div><\/section><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-g4e128-e80df853a61f3a2b71d7f5b2cdf5c407\">\n#top .hr.hr-invisible.av-g4e128-e80df853a61f3a2b71d7f5b2cdf5c407{\nheight:50px;\n}\n<\/style>\n<div  class='hr av-g4e128-e80df853a61f3a2b71d7f5b2cdf5c407 hr-invisible  avia-builder-el-26  el_after_av_textblock  el_before_av_image '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-lkav8zak-fe03dadbde0a65d505e37de9e15a0eb0\">\n.avia-image-container.av-lkav8zak-fe03dadbde0a65d505e37de9e15a0eb0 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-lkav8zak-fe03dadbde0a65d505e37de9e15a0eb0 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-lkav8zak-fe03dadbde0a65d505e37de9e15a0eb0 av-styling- avia-align-center  avia-builder-el-27  el_after_av_hr  avia-builder-el-last '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img decoding=\"async\" fetchpriority=\"high\" class='wp-image-1895 avia-img-lazy-loading-not-1895 avia_image ' src=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/WhatsApp-Image-2023-07-20-at-12.10.07-PM.jpeg\" alt='Flow Control Valve' title='Flow Control Valve'  height=\"386\" width=\"924\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/WhatsApp-Image-2023-07-20-at-12.10.07-PM.jpeg 924w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/WhatsApp-Image-2023-07-20-at-12.10.07-PM-300x125.jpeg 300w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/WhatsApp-Image-2023-07-20-at-12.10.07-PM-768x321.jpeg 768w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/WhatsApp-Image-2023-07-20-at-12.10.07-PM-705x295.jpeg 705w\" sizes=\"(max-width: 924px) 100vw, 924px\" \/><\/div><\/div><\/div><\/p><\/div><div  class='flex_column av-d83bb4-faa3161bb528fd3622bc927872e6a16f av_one_full  avia-builder-el-28  el_after_av_one_full  el_before_av_one_full  first flex_column_div  column-top-margin'     ><section  id=\"types\"  class='av_textblock_section av-lkapc6lg-8985309bc10e7120a85515f71ee8e7af '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h2>Types of Flow Control Valves<\/h2>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-lkapdqm8-5768d37968077aa50dd780871005a619 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><p>There are several types of flow control valves available, each with its unique characteristics and applications. Let&#8217;s explore some of the commonly used types:<\/p>\n<\/div><\/section><\/p><\/div><\/p>\n<div  class='flex_column av-b5k234-1d479ade8b1f9dcdeb2cf0216812b9e1 av_one_full  avia-builder-el-31  el_after_av_one_full  el_before_av_one_full  first flex_column_div  column-top-margin'     ><section  id=\"manualvalve\"  class='av_textblock_section av-lkapji59-252b199de81b970ee023e00c3e0054d3 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>Manual actuated Flow Control valves<\/h3>\n<\/div><\/section><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-ej1rsg-1bf22bdd2953ad5c9a49bece36f07008\">\n#top .hr.hr-invisible.av-ej1rsg-1bf22bdd2953ad5c9a49bece36f07008{\nheight:50px;\n}\n<\/style>\n<div  class='hr av-ej1rsg-1bf22bdd2953ad5c9a49bece36f07008 hr-invisible  avia-builder-el-33  el_after_av_textblock  el_before_av_image '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-lkapprb7-062527bf4d7231585d2d944ed338b109\">\n.avia-image-container.av-lkapprb7-062527bf4d7231585d2d944ed338b109 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-lkapprb7-062527bf4d7231585d2d944ed338b109 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-lkapprb7-062527bf4d7231585d2d944ed338b109 av-styling- avia-align-center  avia-builder-el-34  el_after_av_hr  el_before_av_hr '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img decoding=\"async\" fetchpriority=\"high\" class='wp-image-1893 avia-img-lazy-loading-not-1893 avia_image ' src=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/WhatsApp-Image-2023-07-20-at-11.59.08-AM.jpeg\" alt='Flow Control Valve' title='Flow Control Valve'  height=\"676\" width=\"768\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/WhatsApp-Image-2023-07-20-at-11.59.08-AM.jpeg 768w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/WhatsApp-Image-2023-07-20-at-11.59.08-AM-300x264.jpeg 300w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/WhatsApp-Image-2023-07-20-at-11.59.08-AM-705x621.jpeg 705w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/><\/div><\/div><\/div><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-cp10io-c364ed664c2b8ca5f0a18f3f1db193df\">\n#top .hr.hr-invisible.av-cp10io-c364ed664c2b8ca5f0a18f3f1db193df{\nheight:50px;\n}\n<\/style>\n<div  class='hr av-cp10io-c364ed664c2b8ca5f0a18f3f1db193df hr-invisible  avia-builder-el-35  el_after_av_image  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-lkapmjaj-730aed57ea6baabe8156cd17f5846639 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><p>In general, manual flow control valves equipped with coupling and lever are used for power actuated valves. This allows to add a gear motor or pneumatic piston later on if required. All types of flow control gates are equipped with a switch box containing three limit switches for the positions \u2018open\u2019, \u2018intermediate\u2019 and closed\u2019. Furthermore, there is a potentiometer for remote control indication.<\/p>\n<\/div><\/section><\/p><\/div><div  class='flex_column av-8hbc5c-c0cd2ae35822137ef62768a642af370e av_one_full  avia-builder-el-37  el_after_av_one_full  el_before_av_one_full  first flex_column_div  column-top-margin'     ><section  id=\"pneumaticfcv\"  class='av_textblock_section av-lkaps792-c199cea7799aad1c5656927b8173ccb1 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>Pneumatic controlled Flow control Valve<\/h3>\n<\/div><\/section><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-avzu40-628be98c2d8349ba1f481625f2bf3668\">\n#top .hr.hr-invisible.av-avzu40-628be98c2d8349ba1f481625f2bf3668{\nheight:50px;\n}\n<\/style>\n<div  class='hr av-avzu40-628be98c2d8349ba1f481625f2bf3668 hr-invisible  avia-builder-el-39  el_after_av_textblock  el_before_av_image '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-lkapwxcx-f9bc278fcb0ec209335060e222369a04\">\n.avia-image-container.av-lkapwxcx-f9bc278fcb0ec209335060e222369a04 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-lkapwxcx-f9bc278fcb0ec209335060e222369a04 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-lkapwxcx-f9bc278fcb0ec209335060e222369a04 av-styling- avia-align-center  avia-builder-el-40  el_after_av_hr  el_before_av_hr '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img decoding=\"async\" fetchpriority=\"high\" class='wp-image-1878 avia-img-lazy-loading-not-1878 avia_image ' src=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/pneumatic-1.png\" alt='Flow Control Valve' title='Flow Control Valve'  height=\"620\" width=\"491\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/pneumatic-1.png 491w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/pneumatic-1-238x300.png 238w\" sizes=\"(max-width: 491px) 100vw, 491px\" \/><\/div><\/div><\/div><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-94t3og-bc84f5de746626f5761ab1f46da33e83\">\n#top .hr.hr-invisible.av-94t3og-bc84f5de746626f5761ab1f46da33e83{\nheight:50px;\n}\n<\/style>\n<div  class='hr av-94t3og-bc84f5de746626f5761ab1f46da33e83 hr-invisible  avia-builder-el-41  el_after_av_image  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-lkapz45k-b3968bb54e2b97937111c2a678cb480f '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><p>Pneumatic piston controlled flow control valves are equipped with a double acting pneumatic piston controlled by a special 5\/3 way valve which makes it possible to stop the gate in any position required.<\/p>\n<p>In case of power failure the flow control valve will automatically move into the \u2018closed\u2019 position.<\/p>\n<\/div><\/section><\/p><\/div><div  class='flex_column av-7ybe8g-7a8a844ad4d470e19921bbdf9bc4d3b8 av_one_full  avia-builder-el-43  el_after_av_one_full  el_before_av_one_full  first flex_column_div  column-top-margin'     ><section  id=\"motorfcv\"  class='av_textblock_section av-lkaq1k4n-3c17f0c2122947319b09f3504796ad60 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>Motor controlled Flow control Valve<\/h3>\n<\/div><\/section><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-7oitc0-b675eacc1c81e7cbf1d9de1950ad4f2e\">\n#top .hr.hr-invisible.av-7oitc0-b675eacc1c81e7cbf1d9de1950ad4f2e{\nheight:50px;\n}\n<\/style>\n<div  class='hr av-7oitc0-b675eacc1c81e7cbf1d9de1950ad4f2e hr-invisible  avia-builder-el-45  el_after_av_textblock  el_before_av_image '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-lkaq18bv-624fac55cc54cfddff59f21b9034ef18\">\n.avia-image-container.av-lkaq18bv-624fac55cc54cfddff59f21b9034ef18 img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-lkaq18bv-624fac55cc54cfddff59f21b9034ef18 .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-lkaq18bv-624fac55cc54cfddff59f21b9034ef18 av-styling- avia-align-center  avia-builder-el-46  el_after_av_hr  el_before_av_hr '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img decoding=\"async\" fetchpriority=\"high\" class='wp-image-1881 avia-img-lazy-loading-not-1881 avia_image ' src=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-110727.png\" alt='Flow Control Valve' title='Flow Control Valve'  height=\"617\" width=\"494\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-110727.png 494w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/Screenshot-2023-07-20-110727-240x300.png 240w\" sizes=\"(max-width: 494px) 100vw, 494px\" \/><\/div><\/div><\/div><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-6c5k5c-5db1929509ac0f05ff2b6653b5c83bf9\">\n#top .hr.hr-invisible.av-6c5k5c-5db1929509ac0f05ff2b6653b5c83bf9{\nheight:50px;\n}\n<\/style>\n<div  class='hr av-6c5k5c-5db1929509ac0f05ff2b6653b5c83bf9 hr-invisible  avia-builder-el-47  el_after_av_image  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  class='av_textblock_section av-lkaq3j9b-98a887a967d0d970c03e3e796f3b6fc4 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><p>Motor actuated flow control valves are equipped with a gear motor or with a torque motor. Gear motors can be positioned in four different ways, i.e. \u2018top right\u2019, \u2018top left\u2019, \u2018bottom right\u2019 and \u2018bottom left\u2019. The standard type is top right. The actuating velocities for a full way of 90 degrees are 8, 25, 45 or 60 sec. depending on the requirements.<\/p>\n<\/div><\/section><\/p><\/div><div  class='flex_column av-5nun8g-012d3d7f4cb08dbcb62b948436c72d23 av_one_full  avia-builder-el-49  el_after_av_one_full  el_before_av_one_full  first flex_column_div  column-top-margin'     ><section  id=\"factors\"  class='av_textblock_section av-lkaqbbao-2073f44e9ccb5f6e4dc88bfc0bcd7819 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h2>Factors to consider before choosing the right Flow Control Valve<\/h2>\n<\/div><\/section><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-eudj4-970613f89785e51aaf1d291e3be9b56a\">\n#top .hr.hr-invisible.av-eudj4-970613f89785e51aaf1d291e3be9b56a{\nheight:50px;\n}\n<\/style>\n<div  class='hr av-eudj4-970613f89785e51aaf1d291e3be9b56a hr-invisible  avia-builder-el-51  el_after_av_textblock  el_before_av_textblock '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n<section  id=\"actuation\"  class='av_textblock_section av-lkaqgx8v-452d91f9ef1704c3a1e8c94f08962e0b '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>Actuation<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-lkaqim0o-6c742e0f176c0c2ca0adbdb4ff034a67 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><p>You need to ascertain whether the valve is manually turned on and off by hand or whether an actuator is needed to do so. If you select on the latter, you have chosen the device that will be utilized if a hydraulic or pneumatic actuator is needed.<\/p>\n<\/div><\/section><br \/>\n<section  id=\"material\"  class='av_textblock_section av-lkaqk2sm-b137c437b15523828c96c20903653e63 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>Material<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-lkaqldx5-940575fddcfb65b010acfb5ea2322552 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><p>Considering the material properties and environmental conditions, selecting the right valve is essential for longevity and performance. Factors such as compatibility, corrosion resistance, and temperature range should be taken into account.<\/p>\n<\/div><\/section><br \/>\n<section  id=\"frr\"  class='av_textblock_section av-lkaqlwp2-b8c3f06571145c350fdb90dc59d6c9fa '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>Flow Rate Requirements<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-lkaqm3q6-044bd4ec61e60846d8ecb18f45579f25 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><p>Understanding the required flow rate is essential in choosing the right flow control valve. Different valves have varying capacities, and selecting the appropriate valve size ensures optimal performance and avoids flow restrictions or inefficiencies.<\/p>\n<\/div><\/section><br \/>\n<section  id=\"maintenance\"  class='av_textblock_section av-lkaqnegp-e041a7f30d71b7ead1a7b805c4d523ba '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h3><strong>Maintenance Requirements<\/strong><\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-lkaqoynu-2ed06109381f0d1646edf3a34de63578 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><p>Regular maintenance is necessary to prevent clogs in the gate valve, which must be maintained. As a result, this is the most straightforward approach of giving you gate valves that will last a long time. The gate valves are created in a way that makes cleaning them simple without requiring disassembly.<\/p>\n<\/div><\/section><\/p><\/div><div  class='flex_column av-4h27zk-b92e0fb15683c5a26b7baf87ebea346c av_one_full  avia-builder-el-60  el_after_av_one_full  el_before_av_one_full  first flex_column_div  column-top-margin'     ><section  id=\"case\"  class='av_textblock_section av-lkaqr343-25e67e2f2d9f9269db821bf5164677a1 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h2>Use Case: Cement Industries<\/h2>\n<\/div><\/section><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-ag734-d8313b1b18e521ddef2d4d0bebe6bc4b\">\n#top .hr.hr-invisible.av-ag734-d8313b1b18e521ddef2d4d0bebe6bc4b{\nheight:50px;\n}\n<\/style>\n<div  class='hr av-ag734-d8313b1b18e521ddef2d4d0bebe6bc4b hr-invisible  avia-builder-el-62  el_after_av_textblock  el_before_av_image '><span class='hr-inner '><span class=\"hr-inner-style\"><\/span><\/span><\/div><br \/>\n\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-lkaqrhdf-b39c07c74ca5d82860b8c8e31720621c\">\n.avia-image-container.av-lkaqrhdf-b39c07c74ca5d82860b8c8e31720621c img.avia_image{\nbox-shadow:none;\n}\n.avia-image-container.av-lkaqrhdf-b39c07c74ca5d82860b8c8e31720621c .av-image-caption-overlay-center{\ncolor:#ffffff;\n}\n<\/style>\n<div  class='avia-image-container av-lkaqrhdf-b39c07c74ca5d82860b8c8e31720621c av-styling- avia-align-center  avia-builder-el-63  el_after_av_hr  el_before_av_textblock '   itemprop=\"image\" itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/ImageObject\" ><div class=\"avia-image-container-inner\"><div class=\"avia-image-overlay-wrap\"><img decoding=\"async\" fetchpriority=\"high\" class='wp-image-1886 avia-img-lazy-loading-not-1886 avia_image ' src=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/cement-kiln.png\" alt='Flow Control Valve' title='Flow Control Valve'  height=\"868\" width=\"494\"  itemprop=\"thumbnailUrl\" srcset=\"https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/cement-kiln.png 494w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/cement-kiln-171x300.png 171w, https:\/\/www.koenigconveyors.com\/in\/wp-content\/uploads\/2023\/07\/cement-kiln-401x705.png 401w\" sizes=\"(max-width: 494px) 100vw, 494px\" \/><\/div><\/div><\/div><br \/>\n<section  class='av_textblock_section av-lkaqvf4m-f510857ca795005a5c3634e9321a7c93 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><p>The movement of raw material between the pre-bin and the weighing apparatus is regulated by flow control valves. For this kind of application, electro-pneumatic control devices are employed with pneumatically controlled flow control valves. With the help of a signal exchange with the flowmeter, the material flow is managed.<\/p>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-lkaqwx6n-57595f1cdfaf7197b7898f09351cbf51 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><p>Without using lever arms, toothed racks, or gears, the pneumatic actuators work on the rotating paddle pneumatics principle. Because there are no intervening side forces on the square drive, the pure torque may be delivered. The actuators, which stand out for their lightweight and compact form, require little to no maintenance.<\/p>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-lkaqy4gv-79a2e028f4be9b163782926cbf2fa694 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><p>The actuator mechanism has ventilation choices as well, allowing for manual movement (hand lever). The stand-by equipment&#8217;s flow control gates can be precisely adjusted through remote control to match the main line&#8217;s present operating position. The configuration of a weighing station with flow metering equipment is shown in the above figure.<\/p>\n<\/div><\/section><\/p><\/div><div  class='flex_column av-2lk3f4-25b094042840d0e3fd579f471fbdb294 av_one_full  avia-builder-el-67  el_after_av_one_full  avia-builder-el-last  first flex_column_div  column-top-margin'     ><section  id=\"conclusion\"  class='av_textblock_section av-lkar2caw-4a2c8b0692db104f1e692bf2e6e07f93 '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><h3>Conclusion<\/h3>\n<\/div><\/section><br \/>\n<section  class='av_textblock_section av-lkar30r8-af530476758f3b24afdbe6ea2cc6e18c '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/BlogPosting\" itemprop=\"blogPost\" ><div class='avia_textblock'  itemprop=\"text\" ><p>Flow control valves are essential parts in many sectors because they allow for precise control of fluid flow rates and increase system effectiveness. Industries may streamline their procedures and enhance overall performance by having a thorough awareness of the various flow control valve types, their applications, and the variables to take into account when choosing and maintaining them.<\/p>\n<\/div><\/section><\/p><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":3,"featured_media":1893,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[24],"tags":[],"class_list":["post-1840","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-gates-and-valves"],"_links":{"self":[{"href":"https:\/\/www.koenigconveyors.com\/in\/wp-json\/wp\/v2\/posts\/1840","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.koenigconveyors.com\/in\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.koenigconveyors.com\/in\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.koenigconveyors.com\/in\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.koenigconveyors.com\/in\/wp-json\/wp\/v2\/comments?post=1840"}],"version-history":[{"count":43,"href":"https:\/\/www.koenigconveyors.com\/in\/wp-json\/wp\/v2\/posts\/1840\/revisions"}],"predecessor-version":[{"id":1900,"href":"https:\/\/www.koenigconveyors.com\/in\/wp-json\/wp\/v2\/posts\/1840\/revisions\/1900"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.koenigconveyors.com\/in\/wp-json\/wp\/v2\/media\/1893"}],"wp:attachment":[{"href":"https:\/\/www.koenigconveyors.com\/in\/wp-json\/wp\/v2\/media?parent=1840"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.koenigconveyors.com\/in\/wp-json\/wp\/v2\/categories?post=1840"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.koenigconveyors.com\/in\/wp-json\/wp\/v2\/tags?post=1840"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}